YELLOW JACKET 95760 Refrigerant Recovery Machine, 1/2HP, 115V
Get it by Jun 18, Tuesday
Not eligible for flat shipping. Flat shipping is available on order value € or more and aggregate weight below 5 pounds.
Payment Options Available
Delivery Options Available
Product Specifications:
Item | Refrigerant Recovery Machine |
Depth | 19-5/16" |
Electrical Connections | NEMA 5-15P Male Plug |
Height | 12.5" |
Hose Connection | 1/4" Male Port |
Motor HP | 1/2 |
Operating Temp. Range | 40 to 120 F |
Requires | Connection Hoses & Recovery Tank |
Type | 2-Port |
Voltage | 115 |
Width | 12 13/32" |
Shipping Info:
Ship weight (kg) | 18.02 |
Ship height (cm) | 37.59 |
Ship length (cm) | 55.88 |
Ship width (cm) | 40.13 |
HS code | 8414100000 |
Country of Origin | US |
Product Details:
Features:
- YELLOW JACKET 95760 refrigerant recovery machine features a single-valve changeover for easy switching between liquid and vapour to purge operation.
- This refrigerant recovery machine comes with a compressor protected against liquid refrigerant, ensuring durability and safe operation.
- It is equipped with an automatic shutoff system at 13 or 15 inches of vacuum (depending on the unit) that restarts on pressure rise, enhancing user safety.
- This machine offers compatibility with a range of refrigerants, including HP and MP blends, R-114, R-134A, R-22 and others.
- It comes with electrical connections featuring a NEMA 5-15p male plug and a hose connection of 1/4 inch for convenient use.
- This refrigerant recovery machine requires connection hoses and a recovery tank, ensuring a complete and effective refrigerant recovery process.
- It is ARI-certified for use with HFC and CHFC refrigerants, demonstrating compliance with industry standards and ensuring reliability in refrigerant recovery operations.
Standards and Approvals:
- ISO-9001
Frequently Asked Questions:
Q. Why is it necessary to recover refrigerants?
A. Refrigerants play an essential role in the heat transfer process that allows air conditioning and heating systems to function. Chlorofluorocarbons (CFCs), hydrochlorofluorocarbons (HCFCs) and hydrofluorocarbons are some of the most commonly used refrigerants (HFCs).
Q. What are the three methods of refrigerant recovery?
A.
- Vapor recovery, the push-pull method, and the liquid recovery method are the three different recovery methods.
- Vapour Recovery: In the vapour recovery method, the refrigerant is eliminated from the HVAC system in a vapour state. The recovery unit then condenses the vapour into a liquid and transfers it to the recovery cylinder.
- Push-pull Recovery: This method is used to transfer large amounts of liquid refrigerant. The recovery unit extracts vapour from the recovery cylinder and generates high-pressure discharge gas which forces the liquid out of the HVAC system and back into the recovery cylinder.
- Liquid Recovery Method: In the liquid recovery method, refrigerant is transferred while still in the liquid state. Recovering liquid is suitable for recovering large amounts of refrigerant.
Q. What are the most common applications for refrigerants?
A. To keep production running, refrigerants are used to cool down large data centres and electricity production warehouses. R407C, R410A, R1234ze, and R134a are common refrigerants used for this purpose.
Q. How to set up this YELLOW JACKET 95760 refrigerant recovery machine?
A.
- Firstly, place the machine on a stable surface.
- Install a clean filter screen or filter / dryer to the inlet fitting.
- Connect a hose from the liquid port of the recovery cylinder into the outlet fitting on the unit.
- Connect a hose from the outlet port of a manifold gauge set to the inlet fitting on the unit through the filter / dryer.
- Connect a hose from the selected system's liquid side to the liquid (low pressure) side of the manifold gauge set.
- Connect a hose from the system's vapour side to the vapour (high) side of the manifold gauge set.
- Close all the inlet & outlet valves and place the cylinder on a weighing scale to prevent its overfilling.
Q. What type of cylinders are required for YELLOW JACKET 95760 refrigerant recovery machine?
A.
- The selected cylinder should be an authorised, refillable refrigerant storage cylinder specs.
- Robinair recommends using 400 psi (27.6 bar) cylinders or at least a 350 psi (24.1 bar) cylinder.
- Closed cylinders should be filled up to 80% of their volume to prevent personal injury & equipment damage.
- Recovery cylinders & filter / dryers should be used with only one refrigerant type.
- Refrigerant cylinders should be stored in a cool, dry place.
Product Variants
Product | Model | Type | Width | Depth | Electrical Connections | Height | Hose Connection | Operating Temp. Range | Requires | Price | |
---|---|---|---|---|---|---|---|---|---|---|---|
95762 | Overfill Protection Kit | 21.25" | 13-1/2" | US Plug | 15" | 1/4" | 35 Degrees to 120 Degrees | - | €€1,919.07 | ||
95730 | AC Service System | 568601" | 13-1/2" | NEMA 5-15P Plug | 11.5" | 1/4" | 40 Degrees to 122 Degrees | Connection Hoses and Recovery Tank | - | RFQ
|
Explore Products
- EATON XTAE025C01HP24 IEC Starter
- SPEARS VALVES FVS-040 Foot Valve Screen, Spigot, 4 Size, PVC
- GRAINGER 13516_12_36 Carbon Steel Rectangular Perforated Sheet, 0.06 Inch Thick12 Inch X 36 Inch Size
- EATON CHB110 Type Chb Circuit Breaker, Single-Pole, 10A, #14-8 Awg Wire, 10 Kaic
- WILTON TOOLS 505480
- SALSBURY INDUSTRIES 2185 Lock Bracket, 1 x 1 x 1 Inch Size
- KIPP K0122.92101X30 Adjustable Handle, Teardrop, Zinc, M10 Thread Size, 30 mm Stud Length
Explore More
- Stick Welders
- Laboratory Trays and Pans
- 50 Hz Motors
- Jumper Cables
- Electric Appliance Controls
- Cabinets
- Storage Bins and Containers
- Blowers
- Casters and Wheels
- Files
- SIGNODE Pneumatic Combination Tool
- 3M Heat Shrink Nylon-Insulated Male Disconnect
- HAM-LET Female Connector Stainless Steel Connectors
- KNIPEX Tweezers, Anti Magnetic
- APPLETON ELECTRIC 52 Watt Fluorescent Light Fixture
- COOPER B-LINE Universal Vertical Bend Stringers
- MARATHON MOTORS General Purpose Motors, Single Phase, Totally Enclosed, C Face Footed
- HUMBOLDT Latex Membranes
- WINSMITH SE Encore Series, E30 Size, MDSS Single Reduction Modified Worm Gear Reducers
- BROWNING YCS Series Stock Steel And Cast Iron Minimum Bore Spur Gears, 12 Pitch
Contact us
Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.