SIEMENS LXD63B600 Sentron Molded Case Circuit Breaker, LD, 600 A, 600 VAC, 3 P
Item: AG8RLL
Model: LXD63B600
In Stock
Get it by Jun 19, Wednesday
Not eligible for flat shipping. Flat shipping is available on order value € or more and aggregate weight below 5 pounds.
€3,675.90 /unit
Add To Cart
Request a Quote
Payment Options Available
Delivery Options Available
Product Specifications:
Item | Bolt On Circuit Breaker |
AIC Rating | 35kAIC@480V |
Amps | 600A |
Frame Type | LXD |
Number of Poles | 3 |
Voltage | 600V |
Voltage Type | AC |
Shipping Info:
Ship weight (kg) | 8.27 |
Ship height (cm) | 27.94 |
Ship length (cm) | 10.16 |
Ship width (cm) | 19.05 |
HS code | 8536200020 |
Product Details:
Siemens LXD63B600 Sentron moulded case circuit breaker prevents damage to the circuit due to excess current (overloads) or short circuits in connected receptacles, branch circuits, motors and HVACs / HVARs.
Features:
- Sentron Series moulded case circuit breaker protects QO load centres, panelboards and switchboard distribution panels from overloads or short-circuits.
- The non-interchangeable thermal-magnetic trip unit provides both long-time and instantaneous functions.
- It has a fixed thermal-trip value of 600A and an adjustable magnetic trip value within the range of 3000 - 6000A.
Standards and Approvals:
- UL 489 / IEC 60947-2
Frequently Asked Questions:
Q. What are the different interrupt ratings of this Siemens LXD63B600 Sentron moulded case circuit breaker?
A. This Siemens LXD63B600 breaker has a maximum interrupt rating of 35kA at 480VAC input.
Q. What are the points to inspect before operating this Siemens LXD63B600 Sentron moulded case circuit breaker?
A.
- Keep the area around the breaker clean by using an enclosure. Remove the dust, dirt, grease, moisture, foreign contaminants or any safety hazards near the circuit breaker area.
- Check that the unit's mechanical linkages, like the toggle actuator, are free to move by switching the unit ON & OFF several times.
- Press the optional push-to-trip button at the bottom side of the unit to mechanically test the circuit breaker.
- Inspect the unit of any cracks, chipping, discolouration or any sign of overheating. Tighten the terminals & connectors. Check the mounting hardware.
Q. What is the voltage rating of this Siemens LXD63B600 Sentron moulded case circuit breaker?
A. Siemens LXD63B600 Sentron moulded case circuit breaker functions well on 600V supply.
Explore Products
- CLE-FORCE C69538 Taper Plug and Bottoming Hand Tap Set, Standard, Flute, M10x1.5 Tool Size, Carbon Steel
- TITAN FASTENERS JPR66032
- PROSENSE DPM1-E-H Digital Panel Meter, 1/32 D Inch Size, 10mm 4-Digit Red Led
- HONEYWELL HVFDSB3B0400G131/U SmartVFD BYPASS, 230Vac, 40 Hp, Graphical, NEMA 1 Enclosure
- ELDON JAMES A1428-2-200WP Adapter, 1/4-28 UNF Thread Size, 1/8 Inch Barb, White Polypropylene
- HUBBELL WIRING DEVICE-KELLEMS 03309017
- CASH VALVE FRM-BWZSASNF01-D1 Pressure Regulator, 3/8 Inch Size, Brass Water/Air/Oil/Gas, 1-2 PSI, STL, Fillister Screw
- MILWAUKEE VALVE H87E0130120 Gear Mounting Kit
Explore More
- Hanging Folding Chair and Table Trucks
- Fire Blankets
- Megaphones
- Laboratory Air Compressors
- Storage Bins and Containers
- Air Conditioners
- Fall Protection
- Pressure and Temperature Control Valves
- Putties
- ENPAC Sorbent Berm Replacement Pillow
- EXTECH Precision Milli Ohm Meter Ohms
- SUPER-STRUT C775L Series Lock Nut
- HOFFMAN H20mit Series Type 4X Vent Drains
- VERMONT GAGE NoGo Standard Thread Plug Gages, 1/4-32 Unef
- REELCRAFT Reel Covers
- GRAINGER Seats
- CAROL Hookup Wires
- HUMBOLDT Calibration Tube
- PROTO Diagonal Cutters
Contact us
Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.
SIEMENS LXD63B600 Sentron Molded Case Circuit Breaker, LD, 600 A, 600 VAC, 3 P
€3,675.90 /unit